<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-10 07-20-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 40 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 72 kHz 12217 8,2590
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,77 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 72 kHz MIN: 12 kHz % above 76 kHz: 8,2590 Acquired: 2026/04/10 7.19.20 Total samples: 12217 Equivalent time: 0:10:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,3 dBr MIN: 2,7 dBr AVE: 4,77 dBr % above 12,2 dBr: 0,0 Last value: 5,8 dBr (2026/04/10 7.19.20) 07.06 07.08 07.10 07.12 07.14 07.16 07.18 0 2 4 6 Pm [dBr]